2018 up to now | 2017 | 2016 | 2015 | 2014 | 2013 | 2012

Mailing List - Entries of 2012


[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [QF-Test] Data Driver question


  • Subject: Re: [QF-Test] Data Driver question
  • From: Gregor Schmid <Gregor.Schmid@?.de>
  • Date: Fri, 18 May 2012 21:45:16 +0200

Hi Ivan, Chuck,

that's indeed a good way to achieve what Chuck asked. I'd just like to
add that you can shorten this to

-Test-Suite
--TestSet 1
----Data driver 1
------Data table for outer loop
------Data table for inner loop
----Test case A
----Test case B

i.e you can have more than one level of iteration in a single data
driver.

Best regards,
    Greg

Ivan Boelle <ivan.boelle@?.com> writes:

> You can achieve this by doing something like this:
>
> -Test-Suite
> --TestSet 1
> -- Data driver 1 
> ----TestSet 2
> ---- Data driver 2
> ------Test case A
> ------Test case B
>
> -> TestSet1 contains TestSet2 which contains TestCases
>
> Both Test A and B will be run using data from both drivers.
> If driver 1 has 2 rows and driver 2 has 3 rows then there will be 6 iterations.
> IE: each possible combination Will be run
>
> Le 18 mai 2012 à 19:25, "Hunt,Chuck" <CHUNT1@?.com> a écrit :
>
>     Is it possible to have 2 data drivers?  One with 5 rows for 5 iterations and one with 1 row
>     that will be re-used each of the 5 iterations.
>    
>      
>    
>     Chuck Hunt
>    
>      
>    
>     ━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━
>     CONFIDENTIALITY NOTICE This message and any included attachments are from Cerner Corporation
>     and are intended only for the addressee. The information contained in this message is
>     confidential and may constitute inside or non-public information under international, federal,
>     or state securities laws. Unauthorized forwarding, printing, copying, distribution, or use of
>     such information is strictly prohibited and may be unlawful. If you are not the addressee,
>     please promptly delete this message and notify the sender of the delivery error by e-mail or
>     you may call Cerner's corporate offices in Kansas City, Missouri, U.S.A at (+1) (816)221-1024.

-- 
Gregor Schmid                                Gregor.Schmid@?.de
Quality First Software GmbH                     http://www.qfs.de
Tulpenstr. 41                               Tel: +49 8171 38648-0
DE-82538 Geretsried                         Fax: +49 8171 3864816
GF: Gregor Schmid, Karlheinz Kellerer          HRB München 140833