Re: [qftestJUI] "Client is not connected" message displayed after the client is connected.


  • Subject: Re: [qftestJUI] "Client is not connected" message displayed after the client is connected.
  • From: Karlheinz Kellerer <Karlheinz.Kellerer@?.de>
  • Date: Wed, 16 Feb 2005 08:57:03 -0000

Hi Karthik,

"S, Karthik \(GE Healthcare, non-ge\)" <Karthik.S1@?.com> writes:

> Hi all,
>
> I Started the application from the QftestJUI. The application is started and
> runs properly. When "WAIT" (Immediately after Start command) command is
> executed, the error occurs and the system displays "Client XX is not
> connected". The Record button is disabled.  I couldn't record or Replay the
> sequence.

When the record button stays disabled after the application has started up
properly, this exactly means that qftestJUI was _not_ able to connect to it.

Please check again chapter 3 "Running an application from qftestJUI" in the
user manual to verify your method of starting the SUT is the correct one and
you havn't missed something.

If you don't get it solved, please send me your testsuite and a runlog of the
SUT startup and I will have a look.

Best regards,
    Karl
--
Karlheinz Kellerer                     Karlheinz.Kellerer@?.de
Quality First Software GmbH                    http://www.qfs.de