Quality First Software GmbHgradient
Quality First Software GmbH
ProfessionalTest Automation
Home|Contact
QF-Test  –  The GUI Test Tool for Java and Web Demo VideoDownloadQF-Test BookletQF-Test

Mailing List Archive

Search mailing list archive only
 

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [QF-Test] Nested warning


  • Subject: Re: [QF-Test] Nested warning
  • From: "Damkjar, Lars" <lars.damkjaer@?.com>
  • Date: Tue, 21 Jun 2011 16:28:21 +0200

Ohhh Now i think i got the point. You are saying that I cannot have a (meaning ANY) testcase in a testcase. I thought it was because something like "testcase XX" is calling "testcase XX" is not allowed but it has nothing to do with the name - sorry for that misunderstanding

Lars
_________________________________________________________

Lars Damkjær / Capgemini Danmark A/S / Viby J
Senior Consultant
Mob: +45 5218 9019 / www.capgemini.com
Aahave Parkvej 31, Viby J, 8260
_________________________________________________________



-----Original Message-----
From: Gregor Schmid [mailto:Gregor.Schmid@?.de]
Sent: 21. juni 2011 14:58
To: qftest-list@?.de
Cc: Damkjar, Lars
Subject: Re: [QF-Test] Nested warning


Hi Lars,

given the screenshot in your original mail, start from the
'Test-case' "BookForloebAuto" and go upwards five nodes. There's a
Test-case called s.th. like "Fly...Forloeb" - hard to tell at that
resolution, but definitely a Test-case. So the Test-case
"BookForloebAuto" is nested inside the Test.case "Fly...".

Best regards,
    Greg

"Damkjar, Lars" <lars.damkjaer@?.com> writes:

> Hi
>
> The problem for me is that looking at the image I cannot find anything that is nested?? What is the name or the testcase r testcall that is nested?
>
> There is a testcase with the name "BookForloebAuto" that has a sequence called "BookForløbAuto" but that is not the same name and therefore not nested ... or is it another one?
>
> Lars
>
> _________________________________________________________
>
> Lars Damkjær / Capgemini Danmark A/S / Viby J
> Senior Consultant
> Mob: +45 5218 9019 / www.capgemini.com
> Aahave Parkvej 31, Viby J, 8260
> _________________________________________________________
>
>
>
> -----Original Message-----
> From: Gregor Schmid [mailto:Gregor.Schmid@?.de]
> Sent: 21. juni 2011 08:49
> To: qftest-list@?.de
> Cc: Damkjar, Lars
> Subject: Re: [QF-Test] Nested warning
>
>
> Hi Lars,
>
> of course. Just look at the image you sent of the run-log and work up
> the hierarchy step by step. You've got a 'Test-case' inside a
> 'Test-call' inside a 'Sequence' and that is in another 'Test-case'. So
> this clearly means you've got one 'Test-case' nested inside another.
>
> That's basically OK if you just run the inner Test-case for its side
> effects so that the outer test-case can work. You can ignore the
> warning if you like. But you should ask yourself the following
> questions:
>
> - Does the inner 'Test-case' ever get run on its own?
>
> - If not, why is it a 'Test-case' and not a 'Procedure'?
>
> - How about moving the 'Test-call' out into the 'Test-set' named
>   "ForloebsAftaer" so the inner 'Test-case' will run before the other
>   one?
>
> Best regards,
>     Greg
>
>
> "Damakjar, Lars" <lars.damkjaer@?.com> writes:
>
>> Hi
>>
>> I understand your point but I cannot see in the script I sent you which case is nested?? Can you?
>>
>> Lars
>>
>> _________________________________________________________
>>
>> Lars Damkjær / Capgemini Danmark A/S / Viby J
>> Senior Consultant
>> Mob: +45 5218 9019 / www.capgemini.com
>> Aahave Parkvej 31, Viby J, 8260
>> _________________________________________________________
>>
>>
>>
>> -----Original Message-----
>> From: Gregor Schmid [mailto:Gregor.Schmid@?.de]
>> Sent: 20. juni 2011 18:16
>> To: qftest-list@?.de
>> Cc: Damkjar, Lars
>> Subject: Re: [QF-Test] Nested warning
>>
>>
>> Hi Lars,
>>
>> the QF-Test report format relies on the default structure of QF-Test.
>>
>> A 'Test-case' is the primary unit that represents a logical test.
>> Test-cases can be structured via 'Test-set' and 'Test-suite' nodes.
>>
>> It is possible to call a 'Test-case' via a 'Call test' node from
>> another 'Test-case' because some people insist that they want to do
>> that, but the report cannot represent nested 'Test-cases' properly
>> which is why you get a warning. I would even have thrown an exception
>> in that case, but I got overruled and you can actually disable this
>> warning via the option
>>
>> Replay->Log warning for nested test-cases
>>
>> Best regards,
>>     Greg
>>
>> "Damkjar, Lars" <lars.damkjaer@?.com> writes:
>>
>>> Hi
>>>
>>> I get a warning that i should not use nested testcase that I don’t understand ?? Can anybody help/
>>> explain?
>>>
>>> [cid]
>>>
>>> _________________________________________________________
>>>
>>> Lars Damkjær / Capgemini Danmark A/S / Viby J
>>> Senior Consultant
>>>
>>> Mob: +45 5218 9019 / www.capgemini.com
>>>
>>> Aahave Parkvej 31, Viby J, 8260
>>> _________________________________________________________
>>>
>>> ━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━
>>> Capgemini is a trading name used by the Capgemini Group of companies which includes Capgemini
>>> Danmark A/S, a company registered in Denmark (number 25606965) whose registered office is at Delta
>>> Park 40 - 2665 Vallensbaek Strand.
>>>
>>> This message contains information that may be privileged or confidential and is the property of
>>> the Capgemini Group. It is intended only for the person to whom it is addressed. If you are not
>>> the intended recipient, you are not authorized to read, print, retain, copy, disseminate,
>>> distribute, or use this message or any part thereof. If you receive this message in error, please
>>> notify the sender immediately and delete all copies of this message.

--
Gregor Schmid                                Gregor.Schmid@?.de
Quality First Software GmbH                     http://www.qfs.de
Tulpenstr. 41                               Tel: +49 8171 38648-0
DE-82538 Geretsried                         Fax: +49 8171 3864816
GF: Gregor Schmid, Karlheinz Kellerer          HRB München 140833

Capgemini is a trading name used by the Capgemini Group of companies which includes Capgemini Danmark A/S, a company registered in Denmark (number 25606965) whose registered office is at Delta Park 40 - 2665 Vallensbaek Strand.






This message contains information that may be privileged or confidential and is the property of the Capgemini Group. It is 
intended only for the person to whom it is addressed. If you are not the intended recipient, you are not authorized to 
read, print, retain, copy, disseminate, distribute, or use this message or any part thereof. If you receive this message 
in error, please notify the sender immediately and delete all copies of this message.